Elevated moisture vapour causes most coating and flooring failures. We test the slab first, then size a mitigation system to what the readings actually show.

Since 1990
Commercial and industrial only
1,000 – 160,000 SF
Project range
UltraFlor
10-year warranty available
Next-day response
On most projects
WHAT IT SOLVES

Fixing the cause, not the symptom

Coatings that keep failing

If a coating bubbled, delaminated or turned milky, moisture is the usual culprit. Recoating over it repeats the failure. We establish the transmission rate first.

Flooring adhesive breakdown

Vapour moving up through a slab breaks down adhesives, lifts tile and buckles resilient flooring. The slab looks fine while the floor above it fails.

Warranty and liability

Flooring manufacturers set moisture limits for their warranties. Documented testing protects the installation and everyone specifying it.

TESTING AND MITIGATION

Testing and mitigation are two separate steps

These get conflated. Testing tells you what the slab is doing. Mitigation is the system installed in response. Not every slab that gets tested needs mitigating.

Relative humidity testing

In-situ relative humidity probes read what is happening inside the slab rather than just at the surface, which is what flooring manufacturers reference in their limits.

When mitigation is not needed

If readings come back inside the limits for the specified flooring, no system is required. Testing sometimes saves the cost of mitigation rather than adding it.

HOW A PROJECT RUNS

Four steps, start to handoff

01

Site assessment

We walk the slab, check its condition, test for moisture where it matters, and give you a clear scope with no vague line items.

02

Read and interpret

Readings are taken over the required period and compared against the limits set by the flooring or coating manufacturer.

03

Size the system

Where mitigation is required, the system is sized to the measured transmission rate rather than applied as a blanket assumption.

04

Install and document

The system goes down, the slab is handed off ready for flooring, and the readings are documented for the warranty file.

WHERE WE DO THIS WORK

Colorado headquarters, six-state coverage

All West Surface Prep is based in Commerce City, Colorado and works across Colorado, Wyoming, Utah, Arizona, New Mexico and South Dakota. For Denver metro projects specifically, see our moisture mitigation in Denver page.

Common questions about concrete moisture mitigation

How do you test for moisture?

In-situ relative humidity probes placed into the slab, following ASTM F2170. They read conditions inside the concrete rather than only at the surface, which is what manufacturers reference.

Our coating already failed. Can you fix it?

Yes. We establish why it failed before specifying anything. If moisture caused it, recoating without mitigation would simply repeat the failure.

Does every slab need mitigation?

No. If readings come back within the limits for the specified flooring, no system is needed. That is one reason testing is worth doing first.

How long does testing take?

Probes need a set equilibration period before readings are valid. We confirm that window up front so it can be built into the programme.

Tell us what the floor is doing

Send the facility type, the approximate square footage and any history of flooring or coating failure. You will hear back the same business day.